Medical Equipment

Provide supplies for ICU,sickroom,clinic ect.

Hospital Bed Supplier

Hospital Bed,medical trolley,baby&child bed,other furnitures.

Business Cooperation

ivychi@repumed.com shawn@repumed.com

An optimal combination of invasive and non-invasive ventilator Hospital Breathing Medical Ventilator

An optimal combination of invasive
and non-invasive ventilator

12 ventilation modes fully cover different clinical situations:
Invasive:
VCV, PCV, SIMV (V, P, PRVC), PRVC, SPONT/CPAP, BIVENT/APRV
Non-invasive:
NIV/CPAP, NIV-T, NIV-S/T

Detachable screen

Reduce risk of cross-infection

Comprehensive lung mechanics monitoring

Compliance, airway resistance, PEEPi, RSBI and WOB,
provide references on treatment evaluation and
promote better treatment plan and respiratory care.

Turbine technology made ventilator get rid of air source dependence

High mobility for intra-hospital transport

 

Superior Mobile ICU ventilator

• Comprehensive ICU ventilator including BIVENT and PRVC
• Compact, big capacity battery, no air compressor, intra-hospital mobility
• Flexible device configuration: equipped on a trolley, bed or ceiling pendant
Cost Effective Solution
• Unique metal-based, autoclavable, heated exhalation valve
• Built-in flow sensor, non-consumable design
• Upgradeable ventilation system software, with an available USB port

An Optimal Combination of Invasive and Noninvasive Ventilator
As noninvasive ventilation is used increasingly in a wide range of clinical situations, we offer a dual solution. VG70 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU.

Ventilation Settings
Ventilation Modes
• VCV (A/C), PCV (A/C), PRVC (optional), PSV (optional), STANDBY • SIMV (VCV)+PSV, SIMV (PCV)+PSV, SIMV (PRVC)+PSV
• SPONT/CPAP+PSV
• BIVENT/APRV +PSV (optional)
• NIV/CPAP, NIV-T, NIV-S/T
Enhancements
• Apnea ventilation, Pressure and Flow trigger, Automatic Tube Compensation (ATC), Smart suction • Manual breath, Insp/Exphold, Screen freeze, Nebulization, Lung recruitment
Parameters
Tidal volume (VT)
20-2000ml
Respiratory rate (RR)
1 to 80 bpm
Inspiratory time (Ti)
0.2 to 9 s (adult), 0.2 to 5 s (pediatric)
Inspiratory flow (Flow)
0 to 100 L/min (pediatric), 0 to 180L/min (adult)
Inspiratory pressure (Pinsp)
5 to 70 mbar (or cmH2O)
Inspiratory pressure limit (Pmax)
80 mbar (or cmH2O)
PEEP
0 to 35 mbar (or cmH2O)
Tslope
0 to 2 s
O2 concentration (FiO2)
21 to 100 Vol%
Trigger sensitivity
0.5 to 20 L/min (Flow trigger),
-20 to 0 mbar (or cmH2O) (Pressure trigger)
I/E ratio
1/10 to 4/1
Apnea alarm time
10-60 seconds
Monitoring
• Inspiratory O2 concentration (FiO2), End-expiratory CO2 concentration (etCO2)
• Compliance (dynamic & static), Resistance (R), MVleak, RSBI, WOB, I:E, Vdaw, PEEPi • Pressure-Volume loop, Pressure-Flow loop, Flow-Volume loop
Alarms
Expiratory minute volume (MV) High/Low, Airway pressure (Paw) High/Low,
VTe Low, PEEP High/Low, Insp. O2 concentration (FiO2) High/Low,
End-expiratory CO2 concentration (etCO2) High/Low, fspont High, Apnea alarm, Disconnection, Flow sensor error, Gas supply, Electrical supply & battery failure,
Exhalation obstruction, Apnea backup for low frequency alarm
Dimensions (WxDxH)
375mm x 395mm x 430mm
Weight
17kg (37.5lbs)
Screen
12.1″ TFT color touch screen

Submit Your Sourcing Request

Please complete the form below and our customer support team will be in touch with you shortly. Inquiries submitted through this form will receive priority processing over emails.